Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
1.
Health Econ ; 31 Suppl 1: 25-43, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35762465

RESUMO

Real-world data are considered a potentially valuable source of evidence for assessing medical technologies in clinical practice, but their widespread use is hampered by numerous challenges. Using the case of coronary stents in Italy, we investigate the potential of administrative databases for estimating costs and health outcomes associated with the use of medical devices in real world conditions. An administrative dataset was created ad hoc by merging hospital records from patients admitted between 2013 and 2019 for stent implantations with ambulatory records, pharmaceutical use data and vital statistics. Health outcomes were multifold: all-cause and cardiac mortality and myocardial infarction, within 30 days, 1, 2, 5 years. Costs were estimated from the National Health System perspective. We used multivariable Cox models and propensity score (PS) methods (PS matching; stratification on PS; inverse probability of treatment weighting using PS; PS adjustment). 257,907 coronary stents were implanted in 113,912 patients. For all health outcomes and follow-up times, and across all methods, patients receiving drug-eluting stents (DES) presented lower risk. For all-cause mortality, the DES patient advantage over bare-metal stent (BMS) patients declined over time but remained significant even at 5 years. For myocardial infarction, results remained quite stable. The DES group presented lower cumulative total costs (ranging from 3264 to 2363 Euros less depending on methods). Our results confirm the consolidated evidence of the benefits of DES compared to BMS. The consistency of results across methods suggests internal validity of the study, while highlighting strengths and limitations of each depending on research context. Administrative data yield great potential to perform comparative effectiveness and cost-effectiveness analysis of medical devices provided certain conditions are met.


Assuntos
Stents Farmacológicos/normas , Infarto do Miocárdio/prevenção & controle , Conjuntos de Dados como Assunto , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/economia , Humanos , Itália , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Modelos de Riscos Proporcionais , Fatores de Risco , Stents/efeitos adversos , Stents/economia , Stents/normas , Resultado do Tratamento
4.
Coron Artery Dis ; 31(1): 9-17, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34569990

RESUMO

BACKGROUND: It remains uncertain whether intravascular ultrasound (IVUS) use and final kissing balloon (FKB) dilatation would be standard care of percutaneous coronary intervention (PCI) with a simple 1-stent technique in unprotected left main coronary artery (LMCA) stenosis. This study sought to investigate the impact of IVUS use and FKB dilatation on long-term major adverse cardiac events (MACEs) in PCI with a simple 1-stent technique for unprotected LMCA stenosis. METHODS: Between June 2006 and December 2012, 255 patients who underwent PCI with 1 drug-eluting stent for LMCA stenosis were analyzed. Mean follow-up duration was 1663 ± 946 days. Long-term MACEs were defined as death, nonfatal myocardial infarction (MI) and repeat revascularizations. RESULTS: During the follow-up, 72 (28.2%) MACEs occurred including 38 (14.9%) deaths, 21 (8.2%) nonfatal MIs and 13 (5.1%) revascularizations. The IVUS examination and FKB dilatation were done in 158 (62.0%) and 119 (46.7%), respectively. IVUS use (20.3 versus 41.2%; log-rank P < 0.001), not FKB dilatation (30.3 versus 26.5%; log-rank P = 0.614), significantly reduced MACEs. In multivariate analysis, IVUS use was a negative predictor of MACEs [hazards ratio 0.51; 95% confidence interval (CI) 0.29-0.88; P = 0.017], whereas FKB dilatation (hazard ratio 1.68; 95% CI, 1.01-2.80; P = 0.047) was a positive predictor of MACEs. In bifurcation LMCA stenosis, IVUS use (18.7 versus 48.0%; log-rank P < 0.001) significantly reduced MACEs. In nonbifurcation LMCA stenosis, FKB dilatation showed a trend of increased MACEs (P = 0.076). CONCLUSION: IVUS examination is helpful in reducing clinical events in PCI for LMCA bifurcation lesions, whereas mandatory FKB dilatation after the 1-stent technique might be harmful in nonbifurcation LMCA stenosis.


Assuntos
Angioplastia Coronária com Balão/normas , Infarto do Miocárdio/mortalidade , Revascularização Miocárdica/normas , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Ultrassonografia de Intervenção/normas , Idoso , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/estatística & dados numéricos , Angiografia Coronária/métodos , Stents Farmacológicos/normas , Stents Farmacológicos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Revascularização Miocárdica/métodos , Revascularização Miocárdica/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde/métodos , Modelos de Riscos Proporcionais , Fatores de Risco , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
5.
Coron Artery Dis ; 33(2): 105-113, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074911

RESUMO

AIMS: We aimed to compare the long-term outcomes of patients undergoing percutaneous coronary intervention (PCI) with biodegradable polymer drug-eluting stents (BP-DES) versus durable polymer drug-eluting stents (DP-DES). METHODS AND RESULTS: Among 11 517 PCIs with second-generation DES performed in our institution between 2007 and 2019, we identified 8042 procedures performed using DP-DES and 3475 using BP-DES. The primary outcome was target lesion failure, the composite target lesion revascularization (TLR), target vessel myocardial infarction and death. Propensity score matching was used to create a well-balanced cohort. Mean follow-up was 4.8 years. Of the 3413 matched pairs, 21% were females, and the mean age was 66 years. At 1 year, the primary outcome occurred in 8.3% patients versus 7.1% (P = 0.07), and TLR rate was 3% versus 2% (P = 0.006) in patients with DP-DES and BP-DES respectively. Within 5 years, the primary outcome occurred in 23.1% versus 23.4% (P = 0.44), and the rate of TLR was 7.2% versus 6.5% (P = 0.07) in patients with DP-DES and BP-DES, respectively. CONCLUSION: Similar rates of the composite outcome were observed throughout the entire follow-up. Target lesion revascularization rates were lower in the BP-DES group at 1-year but equalized within 5 years.


Assuntos
Implantes Absorvíveis/normas , Stents Farmacológicos/estatística & dados numéricos , Equipamentos Médicos Duráveis/normas , Implantes Absorvíveis/estatística & dados numéricos , Idoso , Stents Farmacológicos/normas , Equipamentos Médicos Duráveis/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Pontuação de Propensão , Sistema de Registros/estatística & dados numéricos , Resultado do Tratamento
6.
Coron Artery Dis ; 31(1): 18-24, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34086612

RESUMO

BACKGROUND: Ultrathin bioresorbable polymer sirolimus-eluting stents (BP-SESs) may easily lead to acute recoil. This study investigated acute recoil after BP-SES implantation on the basis of intravascular ultrasound (IVUS). METHODS: We enrolled 40 consecutive stents. Absolute acute recoil by quantitative coronary angiography was defined as the difference between the mean diameter of the last inflated balloon (X) and mean lumen diameter of the BP-SES immediately after balloon deflation (Y). Percent (%) acute recoil was defined as (X-Y)×100/X. IVUS was performed within the culprit lesion. Plaque eccentricity, % plaque burden and calcification grade score were assessed using IVUS. Calcification grade was scored on the basis of quadrants. On the basis of the median acute recoil value of 5.0%, the stents were divided into two groups: low (LAR, n = 20) and high % acute recoil (HAR, n = 20). RESULTS: Mean % acute recoil was 5.8 ± 5.3%. Plaque eccentricity, % plaque burden and stent/artery ratio were significantly higher in the HAR group than in the LAR group. Significant differences in % acute recoil were not observed regarding the types of stent diameter. In multivariate logistic regression and multiple linear regression analysis, plaque eccentricity and % plaque burden in the culprit plaque were significant positive predictors for the occurrence of % acute recoil. No significant differences, including clinical outcomes, were found between both groups at follow-up. CONCLUSION: Acute recoil of BP-SESs may be influenced by an eccentric plaque with a large burden, which did not affect long-term outcomes. However, the present study might suggest the proper strategy (e.g. a more exhaustive plaque preparation) before BP-SES implantation in a case with these IVUS characteristics.


Assuntos
Vasos Coronários/cirurgia , Stents Farmacológicos/normas , Implantes Absorvíveis/normas , Implantes Absorvíveis/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/fisiopatologia , Stents Farmacológicos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Sirolimo/farmacologia , Sirolimo/uso terapêutico , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
7.
Platelets ; 33(2): 312-319, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33856288

RESUMO

Stent thrombosis (ST) is a catastrophic event and efforts to reduce its incidence by altering blood-stent interactions are longstanding. A new electret coating technology that produces long-lasting negative charge on stent surface could make them intrinsically resistant to thrombosis. We assessed the thrombogenicity of stents using an annular perfusion model with confocal microscopy, and determined the efficacy of electret coating technology to confer thrombo-resistant properties to standard stents. Using an annular perfusion chamber, Bare Metal Stent (BMS), standard uncoated DES (DES), and Electret-coated DES (e-DES) were exposed to human blood under arterial flow conditions. Deposits of fibrinogen and platelets on the stent surface were analyzed using immunofluorescence staining and confocal microscopy. Surface coverage by fibrinogen and platelets and the deposit/aggregate size were quantified using computerized morphometric analysis. The experimental methodology produced consistent, quantifiable results. Area of stent surface covered by fibrinogen and platelets and the average size of the deposits/aggregates were lowest for e-DES and highest on BMS, with DES in the middle. The size of fibrinogen-deposits showed no differences between the stents. The testing methodology used in our study successfully demonstrated that electret coating confers significant antithrombotic property to DES stents. These findings warrant confirmation in a larger study.


Assuntos
Stents Farmacológicos/normas , Trombose/terapia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Estudo de Prova de Conceito , Resultado do Tratamento
8.
Eur J Med Res ; 26(1): 121, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34641963

RESUMO

BACKGROUND: Percutaneous coronary interventions (PCI) of bifurcation stenoses are both complex and challenging. Stenting strategies share that the stents' side cells must be carefully explored and appropriately prepared using balloons or stents. So far, stent manufacturers have not provided any information regarding side-branch expansion capacity of their stent platforms. AIMS: Given that drug-eluting stent (DES) information regarding their mechanical capacity of side-branch expansion is not available, we aimed to evaluate contemporary DES (Orsiro, BIOTRONIK AG; Xience Sierra, Abbott Vascular; Resolute Integrity, Medtronic; Promus Premier Select, Boston Scientific; Supraflex Cruz, Sahajan and Medical Technologies) by their side-branch expansion behavior using in vitro bench testing. METHODS: In this in vitro study, we analyzed five commercially available DES (diameter 3.0 mm), measuring their side-branch expansion following inflation of different high-pressure non-compliant (NC) balloons (balloon diameter: 2.00-4.00 mm), thereby revealing the morphological characteristics of their side-branch expansion capacities. RESULTS: We demonstrated that all tested contemporary DES platforms could withstand large single-cell deformations, up to 4.0 mm. As seen in our side-branch experiments, DES designs consisting of only two connectors between strut rings did not only result in huge cell areas, but also in larger cell diameters following side-branch expansion compared with DES designs using three or more connectors. Furthermore, the stent cell diameter attained was below the balloon diameter at normal pressure. CONCLUSIONS: We recommend that the expansion capacity of side-branches should be considered in stent selection for bifurcation interventions.


Assuntos
Portadores de Fármacos/normas , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Portadores de Fármacos/química , Humanos
9.
Molecules ; 26(13)2021 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-34279405

RESUMO

The usage of 3D-printing for drug-eluting implants combines the advantages of a targeted local drug therapy over longer periods of time at the precise location of the disease with a manufacturing technique that easily allows modifications of the implant shape to comply with the individual needs of each patient. Research until now has been focused on several aspects of this topic such as 3D-printing with different materials or printing techniques to achieve implants with different shapes, mechanical properties or release profiles. This review is intended to provide an overview of the developments currently described in the literature. The topic is very multifaceted and several of the investigated aspects are not related to just one type of application. Consequently, this overview deals with the topic of 3D-printed drug-eluting implants in the application fields of stents and catheters, gynecological devices, devices for bone treatment and surgical screws, antitumoral devices and surgical meshes, as well as other devices with either simple or complex geometry. Overall, the current findings highlight the great potential of the manufacturing of drug-eluting implants via 3D-printing technology for advanced individualized medicine despite remaining challenges such as the regulatory approval of individualized implants.


Assuntos
Stents Farmacológicos/normas , Impressão Tridimensional , Animais , Stents Farmacológicos/efeitos adversos , Humanos
10.
Circulation ; 143(22): 2143-2154, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33820424

RESUMO

BACKGROUND: Accelerated endothelial healing after targeted antiproliferative drug delivery may limit the long-term inflammatory response of drug-eluting stents (DESs). The novel Supreme DES is designed to synchronize early drug delivery within 4 to 6 weeks of implantation, leaving behind a prohealing permanent base layer. Whether the Supreme DES is safe and effective in the short term and can improve long-term clinical outcomes is not known. METHODS: In an international, 2:1 randomized, single-blind trial, we compared treatment with Supreme DES to durable polymer everolimus-eluting stents (DP-EES) in patients with acute and chronic coronary syndromes. The primary end point was target lesion failure-a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The trial was designed to demonstrate noninferiority (margin of 3.58%) of the Supreme DES at 12 months compared with DP-EES (URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776). RESULTS: From October 2017 to July 2019, a total of 1629 patients were randomly assigned (2:1) to the Supreme DES (N=1086) or DP-EES (N=543). At 12 months, target lesion failure occurred in 57 of 1057 patients (5.4%) in the Supreme DES group and in 27 of 532 patients (5.1%) in the DP-EES group (absolute risk difference, 0.32% [95% CI, -1.87 to 2.5]; Pnoninferiority=0.002]. There were no significant differences in rates of device success, clinically driven target lesion revascularization, or stent thrombosis at 12 months, and the safety composite of cardiovascular death and target vessel myocardial infarction was 3.5% versus 4.6% (hazard ratio, 0.76 [95% CI, 0.46-1.25]) with Supreme DES compared with DP-EES, although rates of combined clinically and non-clinically driven target lesion revascularization at 12 months were higher with Supreme DES. CONCLUSIONS: Among patients with acute and chronic coronary syndromes undergoing percutaneous coronary intervention, the Supreme DES proved to be noninferior to the standard DP-EES. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776.


Assuntos
Proliferação de Células/efeitos dos fármacos , Doença da Artéria Coronariana/terapia , Sistemas de Liberação de Medicamentos/métodos , Stents Farmacológicos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
11.
Circulation ; 143(22): 2155-2165, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33823606

RESUMO

BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.


Assuntos
Antibacterianos/uso terapêutico , Antígenos CD34/metabolismo , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Idoso , Antibacterianos/farmacologia , Feminino , Humanos , Masculino , Sirolimo/farmacologia , Resultado do Tratamento
12.
Coron Artery Dis ; 32(8): 673-680, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33826537

RESUMO

OBJECTIVES: Drug-coated balloons (DCBs) have theoretical advantages over drug-eluting stents (DESs) to facilitate stent healing. We studied whether, in patients undergoing primary coronary interventions (pPCIs), a strategy of DCB after bare-metal stent improves early healing as determined by optical coherence tomography (OCT) compared with new-generation DES. METHODS: pPCI patients were randomized (1:1) to treatment with new-generation sirolimus-eluting stents (DES group) or DCB-strategy. Vessel healing was assessed by OCT at 90 days. RESULTS: Fifty-three patients were randomized (26 DES vs. 27 DCB). At 90 days, both strategies showed a low rate of uncovered struts (3.2 vs. 3.2%, P = 0.64) and a very high and similar rate of covered and apposed struts (96.6 vs. 96.1%, respectively; P = 0.58). However, DCB group had a significantly lower rate of major coronary evaginations (68 vs. 37%, P = 0.026), and more frequently developed a thin homogeneous neointimal layer (20 vs. 70.4%, P = 0.001) suggesting distinct superior healing at 3 months compared to DES. CONCLUSIONS: In pPCI both, sirolimus-DES and DCB-strategy, provide excellent strut coverage at 3 months. However, DCB ensures more advanced and optimal stent healing compared to sirolimus-DES. Further research is needed to determine whether, in patients undergoing pPCI, DCB offers superior long-term clinical and angiographic outcomes than new-generation DES (NCT03610347).


Assuntos
Stents Farmacológicos/normas , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Idoso , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Sirolimo/farmacologia , Sirolimo/uso terapêutico , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos , Resultado do Tratamento
13.
Circulation ; 143(11): 1081-1091, 2021 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-33205662

RESUMO

BACKGROUND: Large-scale randomized comparison of drug-eluting stents (DES) based on durable polymer versus biodegradable polymer technology is currently insufficient in patients with acute coronary syndrome (ACS). The present study aimed to prove the noninferiority of the durable polymer DES (DP-DES) compared with the biodegradable polymer DES (BP-DES) in such patients. METHODS: The HOST-REDUCE-POLYTECH-ACS (Harmonizing Optimal Strategy for Treatment of Coronary Artery Diseases-Comparison of Reduction of Prasugrel Dose or Polymer Technology in ACS Patients) trial is an investigator-initiated, randomized, open-label, adjudicator-blinded, multicenter, noninferiority trial comparing the efficacy and safety of DP-DES and BP-DES in patients with ACS. The primary end point was a patient-oriented composite outcome (a composite of all-cause death, nonfatal myocardial infarction, and any repeat revascularization) at 12 months. The key secondary end point was device-oriented composite outcome (a composite of cardiac death, target-vessel myocardial infarction, or target lesion revascularization) at 12 months. RESULTS: A total of 3413 patients were randomized to receive the DP-DES (1713 patients) and BP-DES (1700 patients). At 12 months, patient-oriented composite outcome occurred in 5.2% in the DP-DES group and 6.4% in the BP-DES group (absolute risk difference, -1.2%; Pnoninferiority<0.001). The key secondary end point, device-oriented composite outcome, occurred less frequently in the DP-DES group (DP-DES vs BP-DES, 2.6% vs 3.9%; hazard ratio, 0.67 [95% CI, 0.46-0.98]; P=0.038), mostly because of a reduction in target lesion revascularization. The rate of spontaneous nonfatal myocardial infarction and stent thrombosis were extremely low, with no significant difference between the 2 groups (0.6% versus 0.8%; P=0.513 and 0.1% versus 0.4%; P=0.174, respectively). CONCLUSIONS: In ACS patients receiving percutaneous coronary intervention, DP-DES was noninferior to BP-DES with regard to patient-oriented composite outcomes at 12 months after index percutaneous coronary intervention. Registration: URL: https://wwwclinicaltrials.gov; Unique identifier: NCT02193971.


Assuntos
Implantes Absorvíveis/normas , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Polímeros/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Medicine (Baltimore) ; 99(43): e22935, 2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33120851

RESUMO

RATIONALE: Recent research shows that in-stent restenosis (ISR) occurs in half of the patients treated with stenting of femoral and popliteal artery for lower extremity arteriosclerotic occlusive disease (LEASO). Combined therapy is mainly used clinically to obtain better medium- and long-term treatment outcomes and reduce the occurrences of reintervention, among which, the combination of excimer laser ablation (ELA) and drug eluting balloon (DEB) is a new and effective choice. PATIENT CONCERNS: A 76-year-old male patient with ISR of right superficial femoral artery after stent implantation was reported. DIAGNOSIS: Rechecking angiography indicated severe occlusion of the right superficial femoral artery. The physical examination showed that bilateral femoral and popliteal arteries were accessible whereas right dorsalis and posterior tibial arteries are unaccessible. Ankleolus brachial index (ABI) was 0.92 for left and 0.58 for right. INTERVENTIONS: We performed the operation with ELA and drug balloon DEB on the right superficial femoral artery under local anesthesia and treated with oral antiplatelet drugs after operation. OUTCOMES: The combination treatment was very successful, and postoperative lower extremity arteriogram showed the blood flow was fluent and fast. No recurrence was discovered 3 months after the operation and he had no obvious symptom of claudication. LESSONS: The combination of ELA and DEB is useful and effective for ISR of peripheral vessel after stent implantation, and this surgical method is worthwhile but need further clinical research for safety confirmation.


Assuntos
Angioplastia com Balão a Laser/métodos , Arteriopatias Oclusivas/etiologia , Lasers de Excimer/normas , Stents/efeitos adversos , Administração Oral , Idoso , Angiografia/métodos , Terapia Combinada , Constrição Patológica/etiologia , Stents Farmacológicos/normas , Artéria Femoral/patologia , Artéria Femoral/cirurgia , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Masculino , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/uso terapêutico , Resultado do Tratamento
15.
Lancet ; 396(10261): 1504-1510, 2020 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-33091360

RESUMO

BACKGROUND: In the treatment of de-novo coronary small vessel disease, drug-coated balloons (DCBs) are non-inferior to drug-eluting stents (DESs) regarding clinical outcome up to 12 months, but data beyond 1 year is sparse. We aimed to test the long-term efficacy and safety of DCBs regarding clinical endpoints in an all-comer population undergoing percutaneous coronary intervention. METHODS: In this prespecified long-term follow-up of a multicentre, randomised, open-label, non-inferiority trial, patients from 14 clinical sites in Germany, Switzerland, and Austria with de-novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention were randomly assigned 1:1 to DCB or second-generation DES and followed over 3 years for major adverse cardiac events (ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation [TVR]), all-cause death, probable or definite stent thrombosis, and major bleeding (Bleeding Academic Research Consortium bleeding type 3-5). Analyses were performed on the full analysis set according to the modified intention-to-treat principle. Dual antiplatelet therapy was recommended for 1 month after DCB and 6 months after DES with stable symptoms, but 12 months with acute coronary syndromes. The study is registered with ClinicalTrials.gov, NCT01574534 and is ongoing. FINDINGS: Between April 10, 2012, and Feb 1, 2017, of 883 patients assessed, 758 (86%) patients were randomly assigned to the DCB group (n=382) or the DES group (n=376). The Kaplan-Meier estimate of the rate of major adverse cardiac events was 15% in both the DCB and DES groups (hazard ratio [HR] 0·99, 95% CI 0·68-1·45; p=0·95). The two groups were also very similar concerning the single components of adverse cardiac events: cardiac death (Kaplan-Meier estimate 5% vs 4%, HR 1·29, 95% CI 0·63-2·66; p=0·49), non-fatal myocardial infarction (both Kaplan-Meier estimate 6%, HR 0·82, 95% CI 0·45-1·51; p=0·52), and TVR (both Kaplan-Meier estimate 9%, HR 0·95, 95% CI 0·58-1·56; p=0·83). Rates of all-cause death were very similar in DCB versus DES patients (both Kaplan-Meier estimate 8%, HR 1·05, 95% CI 0·62-1·77; p=0·87). Rates of probable or definite stent thrombosis (Kaplan-Meier estimate 1% vs 2%; HR 0·33, 95% CI 0·07-1·64; p=0·18) and major bleeding (Kaplan-Meier estimate 2% vs 4%, HR 0·43, 95% CI 0·17-1·13; p=0·088) were numerically lower in DCB versus DES, however without reaching significance. INTERPRETATION: There is maintained efficacy and safety of DCB versus DES in the treatment of de-novo coronary small vessel disease up to 3 years. FUNDING: Swiss National Science Foundation, Basel Cardiovascular Research Foundation, and B Braun Medical.


Assuntos
Angioplastia Coronária com Balão/normas , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/normas , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Resultado do Tratamento
16.
Thorac Cancer ; 11(8): 2155-2162, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32603550

RESUMO

BACKGROUND: CalliSpheres are drug-eluting beads used for tumor artery embolization, with clinical benefits in a number of cancer types. The aim of the study was to examine the clinical benefits and complications of patients with stage II-IV lung cancer treated with CalliSpheres drug-eluting beads for embolization versus conventional vascular interventional treatment. METHODS: This was a prospective cohort study conducted from August 2018 to May 2019. The patients were grouped according to traditional bronchial arterial infusion chemotherapy (infusion group) or bronchial arterial chemoembolization with CalliSpheres drug-eluting beads loaded with adriamycin (CallisSphere group). Short-term effects, serum tumor markers, and adverse reactions during follow-up were compared between the two groups. RESULTS: There were 60 participants enrolled into the study with 30 in each group including 54 men and six women, 42-78 years of age. In the CalliSphere group, compared with the infusion group, the disease control rate was 93.3% versus 73.3% (P = 0.080) and the objective remission rate (ORR) was 86.7% versus 60.0% (P = 0.039); the three- and six-month progression-free survival (PFS) and six-month overall survival (OS) were better in the CalliSphere group (three-month PFS: 96.7% vs. 73.3%, P = 0.026; six-month PFS: 87.5% vs. 57.1%, P = 0.045; six-month OS: 87.5% vs. 52.7%, P = 0.024); after treatment, the tumor markers in the CalliSphere group were lower (CEA: P < 0.001; CYFRA21-1: P = 0.014). There were no differences in adverse reactions between the two groups. CONCLUSIONS: The clinical effect of bronchial arterial chemoembolization with drug-eluting beads on lung cancer is probably significant and could improve the short-term response, PFS, and OS in patients with stage IIIV lung cancer, without increasing severe adverse reactions. KEY POINTS: SIGNIFICANT FINDINGS OF THE STUDY: The clinical effect of bronchial arterial chemoembolization with drug-eluting beads on lung cancer is probably significant and could improve the short-term response, PFS, and OS in patients with stage II-IV lung cancer, without increasing severe adverse reactions. WHAT THIS STUDY ADDS: The ORR, PFS, OS was better in the CalliSphere group than that of infusion group; CEA and CYFRA21-1 were significant lower in CalliSphere group.


Assuntos
Stents Farmacológicos/normas , Bombas de Infusão/normas , Neoplasias Pulmonares/tratamento farmacológico , Adulto , Idoso , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos
18.
Adv Ther ; 37(5): 2210-2223, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32274746

RESUMO

INTRODUCTION: Scoring balloon angioplasty (SBA) for lumen gain prior to stent implantations or drug-coated balloon angioplasty (DCB) is considered an essential interventional tool for lesion preparation. Recent evidence indicates that SBA may play a pivotal role in enhancing the angiographic and clinical outcomes of DCB angioplasty. METHODS: We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292). RESULTS: A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 ± 10.4 mm in the de novo group, and 20.1 ± 8.9 mm (BMS-ISR) and 16.2 ± 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 ± 0.41 mm (de novo), 2.71 ± 0.31 mm (BMS-ISR), and 2.92 ± 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 ± 0.39 mm (de novo), 3.00 ± 0.35 mm (BMS-ISR), and 3.10 ± 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901). CONCLUSIONS: The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/normas , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/normas , Guias de Prática Clínica como Assunto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
19.
J Interv Cardiol ; 2020: 3872704, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32180687

RESUMO

OBJECTIVE: In this study, we sought to compare the efficacy and safety of the Xience Prime/Xience V/Promus EES and Biomatrix/Biomatrix Flex/Nobori BES with resolute integrity/resolute ZES using the grand drug-eluting stent (Grand-DES) registry. BACKGROUND: Currently, new-generation drug-eluting stents (DESs) are used as the standard of care in patients undergoing percutaneous coronary intervention. No study has simultaneously compared everolimus-eluting stent (EES), biolimus-eluting stent (BES), and zotarolimus-eluting stent (ZES). METHODS: Stent-related composite outcomes (target lesion failure) and patient-related composite outcomes were compared in crude and propensity score-matched analysis. RESULTS: Of the 17,286 patients in the Grand-DES group, 5,137, 2,970, and 4,990 patients in the EES, BES, and ZES groups completed a three-year follow-up. In the propensity score-matched cohort, the stent-related outcome (EES vs. BES vs. ZES; 5.9% vs. 6.7% vs. 7.1%, P = 0.226) and patient-related outcomes (12.7% vs. 13.5% vs. 14.3%, P = 0.226) and patient-related outcomes (12.7% vs. 13.5% vs. 14.3%, P = 0.226) and patient-related outcomes (12.7% vs. 13.5% vs. 14.3%, P = 0.226) and patient-related outcomes (12.7% vs. 13.5% vs. 14.3%. CONCLUSIONS: In this robust real-world registry with unrestricted use of EES, BES, and ZES, the three stent groups showed comparable safety and efficacy at the 3-year follow-up.


Assuntos
Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/normas , Segurança de Equipamentos , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Pontuação de Propensão , Sistema de Registros/estatística & dados numéricos , Sirolimo/farmacologia , Resultado do Tratamento
20.
EuroIntervention ; 16(3): 201-209, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32122821

RESUMO

AIMS: We aimed to investigate the association between the use and findings of IVUS with clinical outcomes in the PCI arm of a randomised trial of LMS PCI. METHODS AND RESULTS: The NOBLE trial randomised patients with LMS disease to treatment by PCI or CABG. Of 603 patients treated by PCI, 435 (72%) underwent post-PCI IVUS assessment, 224 of which were analysed in a core laboratory. At five years, the composite of MACCE was 18.9% if post-PCI IVUS was performed versus 25.0% if it was not performed (p=0.45, after adjustment). Overall repeat revascularisation was not reduced (10.6% vs 16.5%, p=0.11); however, LMS TLR was (5.1% vs 11.6%, p=0.01) if IVUS was used. For comparison of stent expansion, LMS MSA was split into tertiles. We found no significant difference in MACCE, death, myocardial infarction or stent thrombosis between tertiles. There was a significant difference between the lower and upper tertiles for repeat revascularisation (17.6% vs 5.2%, p=0.02) and LMS TLR (12.2% vs 0%, p=0.002). CONCLUSIONS: Post-PCI IVUS assessment and adequate stent expansion are not associated with reduced MACCE; however, there is an association with reduced LMS TLR. The use of intracoronary imaging to prevent stent underexpansion in LMS PCI is likely to improve outcomes.


Assuntos
Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Ultrassonografia de Intervenção/métodos , Vasos Coronários/patologia , Stents Farmacológicos/normas , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...